Ductless Fume Hood LBN-DF162 Ductless Fume Hood is a high-efficiency product with ergonomic features that provides excellent containment. It is a simplified ductless fume hood which can exhibit stable performance and is equipped with an electronic control system. It has three side transparent acrylic windows for high containment levels, a 136m3/h airflow volume, and a built-in centrifugal blower with adjustable speed.
Airflow Volume | 136m3/h | ||||||
Worksurface Height | 900 mm | ||||||
Maximum Opening | 650 mm | ||||||
Air Velocity | 0.4 – 0.6 m/s | ||||||
Noise | ≤ 58dB(A) | ||||||
Fluorescent Lamp | 14W × 2 | ||||||
Blower | Built-in | ||||||
Front Window | Acrylic window | ||||||
|
|||||||
Chemical Filter | 2 pcs | ||||||
Power Consumption | 400 W | ||||||
Power Supply | AC220V±10%, 50/60 Hz | ||||||
Internal Dimension (W×D×H) | 1110 × 690 × 740 mm | ||||||
External Dimension (W×D×H) | 1200 × 830 × 2140 mm | ||||||
Package Dimension (W×D×H) | 1350 × 1040 × 1490 mm | ||||||
Gross Weight | 310 Kg |
LCD touch screen control panel, easy to operate
In-built memory function in case of power failure
8° front slope ergonomic design, fatigue free
Temperature and humidity sensors can detect indoor parameters
Three side transparent acrylic windows
Minimal maintenance and environmentally friendly
Extremely low noise and low vibration level
High operator protection to fume and particle hazards
High-capacity filters for more demanding applications
Audible and video alarms for fault detection and changing filters
Ductless Fume Hoods are used for a variety of applications including chemical fume control, powder and dust removal, solvent vapor control, acid gas fumes and other applications that produce hazardous particulates and fumes.
Download Catalog for Ductless Fume Hood LBN-DF162
DownloadLabnic Ductless Fume Hood filters and recirculates air for safe handling of indoor hazardous compounds. They offer adjustable airflow control to ensure user safety. Their filtering technology captures chemical vapours and particulates maintaining air purity. These hoods have illumination to increase visibility while working. Our Ductless Fume Hood is suitable for electronics, pharmaceutical research, and chemical processing.
Airflow Volume : 136m3/h
Worksurface Height : 900 mm
Maximum Opening : 650 mm
Air Velocity : 0.4 – 0.6 m/s
Airflow Volume : 432m3/h
Worksurface Height : 900 mm
Maximum Opening : 650 mm
Air Velocity : 0.4 – 0.6 m/s
Airflow Volume : 547m3/h
Worksurface Height : 900 mm
Maximum Opening : 650 mm
Air Velocity : 0.4 – 0.6 m/s
Air Velocity : 0.4 ~ 0.6 m/s
Airflow Volume : 432 m³/h
Work Surface Height : 900 mm
Maximum Opening : 650 mm
Labnic PP Spray Fume Hood is built with durable, high-quality polypropylene (PP) material resistant to various chemicals and corrosion. They feature customizable countertop options, including solid core, PP, and ceramic materials. Their exhaust system optimizes airflow and reduces harmful fumes. These hoods have integrated control panels making it easy to manage lighting, circuits, and airflow. Our PP Spray Fume Hood includes an adjustable sash for improved visibility and a comfortable workspace.
Material : Porcelain white PP, 8mm thickness
Airflow Velocity : 0.3 ~ 0.8 m/s
Exhaust Volume : 1130 m3 /h
Waterproof Socket : Two, total load ≤500 W
Material : Porcelain white PP, 8mm thickness
Airflow Velocity : 0.3 ~ 0.8 m/s
Exhaust Volume : 560 m3 /h
Waterproof Socket : Two, total load ≤500 W
Material : Porcelain white PP, 8mm thickness
Airflow Velocity : 0.3 ~ 0.8 m/s
Exhaust Volume : 920 m3 /h
Waterproof Socket : Two, total load ≤500 W
Material : Porcelain white PP, 8mm thickness
Airflow Velocity : 0.3 ~ 0.8 m/s
Exhaust Volume : 700 m3 /h
Waterproof Socket : Two, total load ≤500 W
Labnic Walk-In Fume Hood is designed to handle large-scale experiments with ease. They are equipped with high-capacity filters for demanding operations. Their built-in memory function retains settings during power failure. They feature water and gas taps, along with gas and water valves for added safety. Our Walk-In Fume Hood is ideal for chemical fume control, powder and dust removal, solvent vapour control and more.
Maximum Opening : 1300 mm
Exhaust Air Flow Volume : 1500m3/h
Inflow Air Velocity : 0.3 – 0.8 m/s
Noise : ≤62 dB
Maximum Opening : 1300 mm
Exhaust Air Flow Volume : 1150m3/h
Inflow Air Velocity : 0.3 – 0.8 m/s
Noise : ≤62 dB
Maximum Opening : 1300 mm
Exhaust Air Flow Volume : 1850m3/h
Inflow Air Velocity : 0.3 – 0.8 m/s
Noise : ≤62 dB
Labnic Ducted Fume Hood offer precise airflow for effectively removing hazardous fumes and airborne contaminants. They provide adjustable front windows for easy and safe operation. These hoods are made of premium material for durability and stability. They have intuitive interface for user-friendly process. Our safety-compliant Ducted Fume Hood ensures optimal protection and performance for versatile applications in laboratories and industries.
External Dimension : 1200 × 800 × 2550 mm
Internal Dimension : 990 × 605 × 900 mm
Maximum Opening : 500 mm
Air Velocity : 0.3m/s to 0.8 m/s