WhatsApp Get Quote
Gas Chromatography System LBN-GC111
Gas Chromatography System LBN-GC111

Gas Chromatography System LBN-GC111

Gas Chromatography System LBN-GC111 delivers high-precision analytical performance with advanced temperature, flow, and pressure control supported by a quad-core processor. It features a 10.1-inch high-definition touch screen for intuitive operation and clear visualization. Equipped with a self-tuning PID algorithm, remote browser-based control, and QR-code column information loading for smart automation. Integrated multi-detector support (FID, ECD, TCD, FPD, MSD) and high-speed 1000Hz data acquisition with secure electronic signature reporting. Our Gas Chromatography System is ideal for petrochemical testing, pharmaceuticals, environmental monitoring, food safety laboratories, research institutions, and quality control applications.

Retention Time Reproducibility < 0.008% or < 0.0008 min
Peak Area Reproducibility ≤ 1% RSD
Inlet Type Split / Spitless Inlet Ports
Maximum Inlet Temperature 450°C
Electronic Pressure Control Accuracy 0.001 psi
Control Range 0 to 100 psi (0 to 150 psi optional)
Maximum Split Ratio 12,500:1
Column Oven Temperature Range +4°C to 450°C above room temperature
Temperature Precision ≤ 0.1°C
Max Heating Rate ≥ 75°C/min or ≥ 120°C/min (optional)
Column Cooling Time 450°C to 50°C in < 5 min
Detector Options FID, ECD, TCD, FPD, MSD
FID Max Operating Temp 450°C
FID Minimum Detection Limit ≤1.5 pg/s
FID Linear Range ≥10⁷
ECD Minimum Detection Limit ≤6 × 10⁻¹⁵ g/mL
ECD Linear Range ≥10³
Autosampler Capacity 16 Sample Positions
Injection Volume 0.1 to 5 mL
Data Acquisition Rate Up to 1000 Hz
Remote Control Mobile / Tablet / PC Browser Based
Workstation Software Electronic Signature, Batch Processing
Power Supply 220V ±10%, 50Hz ±2%
Ambient Temperature 5°C–40°C
Relative Humidity 20% to 85% RH
  • Quad-Core Intelligent Control System
  • Rapid Temperature Ramp Capability
  • High-Accuracy Electronic Pressure Control
  • Multi-Stage Program Heating Options
  • Remote Mobile Device Operation
  • Smart Column QR Identification
  • One-Click Batch Data Processing
  • Automatic Flame Re-Ignition System
  • High-Temperature Chamber Protection

Liquid Autosampler, 150 Positions 1 Set

  • Split/Split Less Injection Port with EFC Control 1 Set

  • Liquid Autosampler, 16 Positions 1 Set

  • FID Detector (EPC Component) 1 Set

  • SE-30 Column 1 Pcs

Gas Chromatography System LBN-GC111 is ideal for petrochemical analysis, pharmaceutical testing, environmental monitoring, food safety inspection, forensic toxicology, research laboratories, universities, and industrial quality control applications.

Gas Chromatography System LBN-GC111 is ideal for petrochemical analysis, pharmaceutical testing, environmental monitoring, food safety inspection, forensic toxicology, research laboratories, universities, and industrial quality control applications.

Most Frequently Asked Questions

1. What analytical applications is the Gas Chromatography System LBN-GC111 designed for ?

Ans. The Gas Chromatography System LBN-GC111 is designed for high-precision qualitative and quantitative analysis in petrochemical testing, pharmaceutical analysis, environmental monitoring, food safety laboratories, research institutions, and quality control applications.

2. How does the Gas Chromatography System LBN-GC111 ensure precise temperature and pressure control?

Ans. The Gas Chromatography System LBN-GC111 utilizes a quad-core intelligent control system with a self-tuning PID algorithm and high-accuracy electronic pressure control to maintain stable temperature, flow, and pressure conditions throughout analysis.

3. What detector options are supported by the Gas Chromatography System LBN-GC111?

Ans. The Gas Chromatography System LBN-GC111 supports multiple detectors including FID, ECD, TCD, FPD, and MSD, allowing flexible configuration for diverse analytical requirements.

4. How does the Gas Chromatography System LBN-GC111 improve operational efficiency?

Ans. The Gas Chromatography System LBN-GC111 features A10.1-inch high-definition touch screen, one-click batch data processing, smart column QR-code identification, and high-speed 1000 Hz data acquisition for efficient and streamlined workflows.

5. What remote operation capabilities are available in the Gas Chromatography System LBN-GC111?

Ans. The Gas Chromatography System LBN-GC111 supports remote browser-based control via mobile devices, tablets, and PCs, enabling convenient monitoring and operation from multiple platforms.

6. How does the Gas Chromatography System LBN-GC111 support data integrity and compliance?

Ans. The Gas Chromatography System LBN-GC111 is integrated with workstation software that supports electronic signatures, secure data handling, and batch processing to meet laboratory documentation and compliance requirements.

7. What features support high-speed and high-resolution analysis in the Gas Chromatography System LBN-GC111?

Ans. The Gas Chromatography System LBN-GC111 offers rapid temperature ramping up to 75°C/min (120°C/min optional), fast column cooling, and high-sensitivity detector performance for accurate and high-resolution chromatographic analysis.

8. What is gas chromatography-mass spectrometry?

Ans. It is an analytical technique that combines gas chromatography and mass spectrometry to separate and identify chemical compounds in a sample.

9. What is gas chromatography-mass spectrometry used for?

Ans. It is used on forensic analysis, environmental testing, food safety, pharmaceutical research, and chemical analysis.

10. What types of samples can be analyzed using gas chromatography-mass spectrometry?

Ans. It is commonly used for volatile and semi-volatile organic compounds in gases, liquids, and solids.

11. What gases are used in gas chromatography-mass spectrometry?

Ans. Helium, nitrogen, or hydrogen are commonly used carrier gases in the gas chromatograph.

12. How long does a gas chromatography-mass spectrometry analysis take?

Ans. The duration varies typically ranges from a few minutes to an hour, depending on the complexity of the sample.

Gas Chromatography-Mass Spectrometry Models

Gas Chromatography System LBN-GC111 delivers high-precision analytical performance with advanced temperature, flow, and pressure control supported by a quad-core processor. It features a 10.1-inch high-definition touch screen for intuitive operation and clear visualization. Equipped with a self-tuning PID algorithm, remote browser-based control, and QR-code column information loading for smart automation. Integrated multi-detector support (FID, ECD, TCD, FPD, MSD) and high-speed 1000Hz data acquisition with secure electronic signature reporting. Our Gas Chromatography System is ideal for petrochemical testing, pharmaceuticals, environmental monitoring, food safety laboratories, research institutions, and quality control applications.

Gas Chromatography–Mass Spectrometry System LBN-GC122

  • Mass Range: 0.5 amu – 1250 amu
  • Maximum Scan Speed: 20,000 amu/s

Gas Chromatograph-Mass Spectrometer LBN-GC121

  • GC Flow Rate: 20 to 50 ml/min
  • Maximum Flow Rate: 20 to 55 ml/min