High Speed Centrifuge LBN-HC145 is a clinical benchtop model that runs at a maximum speed of 16000 rpm with a maximum RCF OF 17000 × g. It adopts brushless motors exhibit minimized energy use, long life, high output, low vibration and low noise thereby making it safe, reliable and user friendly. Automatic lid opening and control panel with a touchscreen display are its unique characteristics that facilitates a simple user interface for immediate, effortless productivity, operation monitoring and easy cleaning.
Maximum RPM | 16000 rpm |
Maximum RCF | 17000 x g |
Timer | 0 to 99 min |
Rotor capacity | 1.5 ml/2 ml ×12 (standard) |
Voltage | 110 V 60 Hz /220 V 50 Hz |
Dimension (W×D×H) | 320 x 340 x 280 mm |
Gross weight/Net weight | 9 kg |
Maintanence free induction brushless motor drive for safe, quiet and smooth operation
Strong plastic case with metal lid
Overspeed and imbalance monitoring systems to detect and control rotor speed and rotor imbalance
Error code display system where an error code will be displayed on the display screen if any problem arises during operation
LCD display system to indicate rotational speed rates, RCF and time
Innovative control panel with a touch screen that is easy to operate
Automatic lid opening at the end of the run to prevent sample warming and allow for easy access
Adjustable speed rates to ensure rapid seperation
It is widely applied in the fields of biology, pharmacology and agriculture and are ideal for cellular and molecular biology work with clinical preparations and industrial applications.
Download Catalog for High Speed Centrifuge LBN-HC145
DownloadMaximum Speed : 10000 r/min
Maximum RCF : 11000×g
Time Range : 0 to 999 min
Power Supply : AC220V 50Hz 8A
Maximum Capacity : Angle rotor 1.5/2 ml×12
Maximum Speed : 16000 r/min
Maximum RCF : 18320×g
Time Range : 0 to 99 min
Maximum Capacity : Angle rotor 1.5/2 ml×12
Maximum Speed : 16000 r/min
Maximum RCF : 18320×g
Time Range : 0 to 99 min
Maximum RPM : 16000 RPM, stepless speed adjustment, LED display speed and timer
Maximum RCF : 17000×g
Timer : 0 to 99min
Rotor capacity : 1.5ml/2ml×12 (standard)
Maximum RPM : 16000 rpm
Maximum RCF : 17000× g
Timer : 0 to 99 min
Rotor capacity : Angle rotor 1.5 ml/2 ml ×12 (standard)
Maximum Speed Range : 0 to 6000 rpm
Speed Accuracy : ± 10 rpm
Maximum RCF : 5040 xg
Timer Range : 0 to 99 min
Maximum RPM : 12000 rpm
Maximum RCF : 15800 × g
Timer Range : 0 to 99 min
Speed Accuracy : ± 50 r/min
Maximum RPM : 4000 rpm
Maximum RCF : 1780 × g
Timer : 0 to 99 min
Rotor capacity : Angle rotor 15 ml / 10 ml × 8
Maximum Speed : 12000 rpm
Maximum RCF : 15800 × g
Rotor Capacity : 24 Pieces of Capillary
Noise : ≤ 55dB
Speed Range : 200 to 14000 rpm, Increment of 10 rpm
Maximum RCF : 18620 ×g
Speed Accuracy : ±20 rpm
Rotor : 2 types
Maximum Speed : 18500 rpm
Maximum RCF : 19920 × g
Noise : ≤ 60dB
Time : 0 to 99 min
Maximum RPM : 12000 rpm
Maximum RCF : 15300xg
Timer : 0 to 30 minutes
Rotor capacity : ø 1.5 75 mmx24 capillary tubes
Capacity : 1.5ml×12 Angle rotor
0.5ml×12 Angle rotor
Maximum speed : 16000 r/min
Maximum RCF : 18560×g
Time Range : 0 to 99 min
Maximum RPM : 20000 RPM, stepless speed adjustment, LED display speed, RCF and timer
Maximum RCF : 26500xg
Timer : 0-99min
Rotor capacity : Angle Rotor 1.5ml/2ml x12 (standard)
Maximum speed : 22000 r/min
Maximum RCF : 18560×g
Time Range : 0 to 99 min
Dimension (W×D×H) : 630×470×350 mm
Maximum Speed : 24000 rpm
Maximum RCF : 47800 × g
Maximum Capacity : 4 x100ml
Speed Accuracy : ± 10 rpm
Maximum RPM : 20000 RPM, stepless speed adjustment, LED display speed, RCF and timer
Maximum RCF : 26500xg
Timer : 0-99min
Rotor capacity : Angle Rotor 1.5ml/2ml x12 (standard)
Maximum Speed : 500 to 4000 r/min
Maximum RCF : 2220xg
Maximum Capacity : 125/10 ml vacuum blood tube
Speed Regulation Accuracy : ±30 r/min
Maximum Speed : 4000r/min
Maximum Capacity : 4 × 100ml
Maximum Centrifugal Force : 3150 × g
Speed Accuracy : ± 10r /min
Maximum RPM : 4000 rpm
Maximum RCF : 2325 × g
Timer : 0 to 99 min
Rotor capacity : 20 ml×12 (standard)
Maximum speed : 4000 rpm
Maximum RCF : 880 × g
Rotor capacity : 0.2 ml × 6, 0.5 ml × 6, 1.5 ml × 6, 2 ml × 6, 0.2 ml PCR tube × 16(double rows)
Voltage : 100 to 250 V 50 to 60 Hz