Ion Chromatograph LBN-IC174 operates on reagent-free ion chromatography technology with in-line eluent generation via water electrolysis. It is equipped with a high-pressure pump capable of withstanding up to 42 MPa. Built-in multi-detector compatibility includes conductivity, electrochemical, UV and fluorescence detectors. Integrated with a cell volume of ≤ 0.4µL and a detection range of 0 to 45000µS/cm. Our Ion Chromatograph are essential for applications in environmental, pharmaceutical, and clinical laboratories.
Qualitative Repeatability | ≤0.05% |
---|---|
Quantitative Repeatability | ≤0.3% |
Pump System Flow Rate | 0.001 to 12.000mL/min |
Pump System Pressure Range | 0 to 42MPa |
Pump System Flow Rate Setting Error | Less Than ±0.1% |
Pump System Flow Rate Stability | Less Than ±0.1% |
Eluent Flow Rate Range | 0.001 to 3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1 to 100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler I Quantitative Repeatability | Full Loop Injection Less Than 0.5%RSD |
Autosampler I Linearity | Greater Than 0.9995 |
Autosampler I Injection Positions | 48 Positions |
Autosampler I Working Temperature | 10 to 40°C |
Autosampler I Sample Bottle | 5mL/100mL |
Autosampler I Injection Volume | 10μL to 400μL |
Autosampler II Injection Positions | 120/64 Positions for Optional |
Autosampler II Cooling Temperature | 4 to 30°C |
Autosampler II Injector | Standard 500μL, Options 250μL, 100μL, 2500μL |
Column Oven Temperature Range | Room temperature, +5℃ to 70℃ |
Column Oven Temperature Control Stability | ≤0.1°C |
Column Oven Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Suppressor Pressure Resistance | 3Mpa |
Baseline Noise | ≤0.0003μS/cm |
Baseline Drift | ≤0.001μS·cm to 1/30min |
Min Detection Concentration (Cl-) | ≤0.0001μg/mL |
Min Detection Concentration (Li+) | ≤0.00005μg/mL |
Min Detection Concentration (NO3-) | ≤0.001μg/mL |
Min Detection Concentration (Na+) | ≤0.001μg/mL |
Min Detection Concentration (Ca2+) | ≤0.005μg/mL |
Conductivity Detector Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Detection Range | 0 to 45000μS/cm |
Conductivity Detector Temperature Setting Error | ±0.01°C |
Ampere Detector Drive Voltage Range | -2.048V to +2.048V |
Ampere Detector Drive Voltage Resolution | 0.001V |
Ampere Detector Single Input Range | Integral Mode, 50pC to 200µC |
DC mode | 1pA to 74µA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Power Supply | 220V, 50Hz |
Mainframe Dimension | 550 × 300 × 700mm |
Autosampler Dimension | 376 × 556 × 360 mm |
Mainframe Packing Dimension | 710 × 430 × 890mm |
Autosampler Packing Dimension | 600 × 520 × 630mm |
Net Weight | 80kg |
Gross Weight | 93kg |
Intelligent and powerful hyphenated technology
Simplified flow path
Chemically inert non-metallic flow path
High precision temperature controller
Air-bathing column oven
Easy operation and maintenance
Ampere Detector
Ion Chromatograph LBN-IC174 is widely used in the chemical industry, pharmaceutical industry, environmental protection, sanitary and epidemic prevention, semiconductor manufacturing, etc.