Ion Chromatograph LBN-IC174 operates on reagent-free ion chromatography technology with in-line eluent generation via water electrolysis. It is equipped with a high-pressure pump capable of withstanding up to 42 MPa. Built-in multi-detector compatibility includes conductivity, electrochemical, UV and fluorescence detectors. Integrated with a cell volume of ≤ 0.4µL and a detection range of 0 to 45000µS/cm. Our Ion Chromatograph are essential for applications in environmental, pharmaceutical, and clinical laboratories.
| Qualitative Repeatability | ≤0.05% |
| Quantitative Repeatability | ≤0.3% |
| Pump System Flow Rate | 0.001 to 12.000mL/min |
| Pump System Pressure Range | 0 to 42MPa |
| Pump System Flow Rate Setting Error | Less Than ±0.1% |
| Pump System Flow Rate Stability | Less Than ±0.1% |
| Eluent Flow Rate Range | 0.001 to 3.000ml/min |
| Eluent Concentration Range | KOH/MSA 0.1 to 100.0mM |
| Accuracy of Concentration | 0.1mM |
| Max Working Pressure | 21Mpa (3000psi) |
| Autosampler I Quantitative Repeatability | Full Loop Injection Less Than 0.5%RSD |
| Autosampler I Linearity | Greater Than 0.9995 |
| Autosampler I Injection Positions | 48 Positions |
| Autosampler I Working Temperature | 10 to 40°C |
| Autosampler I Sample Bottle | 5mL/100mL |
| Autosampler I Injection Volume | 10μL to 400μL |
| Autosampler II Injection Positions | 120/64 Positions for Optional |
| Autosampler II Cooling Temperature | 4 to 30°C |
| Autosampler II Injector | Standard 500μL, Options 250μL, 100μL, 2500μL |
| Column Oven Temperature Range | Room temperature, +5℃ to 70℃ |
| Column Oven Temperature Control Stability | ≤0.1°C |
| Column Oven Temperature Setting Error | 0.05°C |
| Column Capacity | 250mm and 150mm |
| Suppressor Dead Volume | 50μL |
| Suppression Capacity | 170ueq/min |
| Suppressor Pressure Resistance | 3Mpa |
| Baseline Noise | ≤0.0003μS/cm |
| Baseline Drift | ≤0.001μS·cm to 1/30min |
| Min Detection Concentration (Cl-) | ≤0.0001μg/mL |
| Min Detection Concentration (Li+) | ≤0.00005μg/mL |
| Min Detection Concentration (NO3-) | ≤0.001μg/mL |
| Min Detection Concentration (Na+) | ≤0.001μg/mL |
| Min Detection Concentration (Ca2+) | ≤0.005μg/mL |
| Conductivity Detector Cell Volume | ≤0.4μL |
| Detector Resolution | 0.00238nS/cm |
| Detection Range | 0 to 45000μS/cm |
| Conductivity Detector Temperature Setting Error | ±0.01°C |
| Ampere Detector Drive Voltage Range | -2.048V to +2.048V |
| Ampere Detector Drive Voltage Resolution | 0.001V |
| Ampere Detector Single Input Range | Integral Mode, 50pC to 200µC |
| DC mode | 1pA to 74µA |
| Cell Volume | <0.2μL |
| Min Detection Concentration | I: 0.001μg/mL |
| Power Supply | 220V, 50Hz |
| Mainframe Dimension | 550 × 300 × 700mm |
| Autosampler Dimension | 376 × 556 × 360 mm |
| Mainframe Packing Dimension | 710 × 430 × 890mm |
| Autosampler Packing Dimension | 600 × 520 × 630mm |
| Net Weight | 80kg |
| Gross Weight | 93kg |
Ampere Detector
Ion Chromatograph LBN-IC174 is widely used in the chemical industry, pharmaceutical industry, environmental protection, sanitary and epidemic prevention, semiconductor manufacturing, etc.
Ion Chromatograph LBN-IC174 is widely used in the chemical industry, pharmaceutical industry, environmental protection, sanitary and epidemic prevention, semiconductor manufacturing, etc.
Ion Chromatograph LBN-IC174 operates on reagent-free ion chromatography technology with in-line eluent generation via water electrolysis. It is equipped with a high-pressure pump capable of withstanding up to 42 MPa. Built-in multi-detector compatibility includes conductivity, electrochemical, UV and fluorescence detectors. Integrated with a cell volume of ≤ 0.4µL and a detection range of 0 to 45000µS/cm. Our Ion Chromatograph are essential for applications in environmental, pharmaceutical, and clinical laboratories.