Labnic Pipettes and Micropipettes ensure precise and accurate volume measurement. Their lightweight design minimizes fatigue during repetitive tasks. Their ergonomic design ensures comfort during extended use. They are compatible with disposable tips, minimizing the risk of cross-contamination. Our Pipettes and Micropipettes are compatible with tip boxes and variable volume options for storage and precise handling.

Pipette Tip Box LBN-PB100

Pipette Tip Volume: 1000 µL

Pack Size: 100 holes

Pieces: 100pcs

Color: Blue

★★★★☆

Variable Volume Pipette LBN-VP100

Volume Range: 10 to 100 μL

Increment: 1 μL

Test Volume: 100 μL, 50 μL, 10 μL

Accuracy Error: 100 μL: 0.8 μL, 0.80%<br/> 50 μL: 0.5 μL, 1.00%<br/> 10 μL: 0.3 μL, 3.00%

★★★★★

Variable Volume Pipette LBN-VP101

Volume Range: 0.5 to 10 μL

Increment: 0.1 μL

Test Volume: 10 μL, 5 μL, 1 μL

Accuracy Error: 10 μL: 0.1 μL, 1.00%<br/> 5 μL: 0.075 μL, 1.50%<br/> 1 μL: 0.025 μL, 2.50%

★★★★★
Variable Volume Pipette LBN-VP102

Volume Range: 2 to 20 μL

Increment: 0.5 μL

Test Volume: 20 μL, 10 μL, 2 μL

Accuracy Error: 20 μL: 0.18 μL, 0.90%<br/> 10 μL: 0.12 μL, 1.20%<br/> 2 μL: 0.06 μL, 3.00%

★★★★☆
Variable Volume Pipette LBN-VP103

Volume Range: 5 to 50 μL

Increment: 0.5 μL

Test Volume: 50 μL, 25 μL, 5 μL

Accuracy Error: 50 μL: 0.3 μL, 0.60%<br/> 25 μL: 0.225 μL, 0.90%<br/> 5 μL: 0.1 μL, 2.00%

★★★★★

Variable Volume Pipette LBN-VP104

Volume Range: 20 to 200 μL

Increment: 1 μL

Test Volume: 200 μL, 100 μL, 20 μL

Accuracy Error: 200 μL: 1.2 μL, 0.60%<br/> 100 μL: 0.8 μL, 0.80%<br/> 20 μL: 0.6 μL, 3.00%

★★★★★

Variable Volume Pipette LBN-VP105

Volume Range: 50 to 200 μL

Increment: 1 μL

Test Volume: 200 μL, 100 μL, 50 μL

Accuracy Error: 200 μL: 1.2 μL, 0.60%<br/> 100 μL: 0.8 μL, 0.80%<br/> 50 μL: 0.5 μL, 1.00%

★★★★★

Variable Volume Pipette LBN-VP106

Volume Range: 200 to 1000 μL

Increment: 5 μL

Test Volume: 1000 μL, 500 μL, 200 μL

Accuracy Error: 1000 μL: 6 μL, 0.60%<br/> 500 μL: 3.5 μL, 0.70%<br/> 200 μL: 1.8 μL, 0.90%

★★★★☆
Variable Volume Pipette LBN-VP107

Volume Range: 1000 to 5000 μL

Increment: 50 μL

Test Volume: 5000 μL, 2500 μL, 1000 μL

Accuracy Error: 5000 μL: 25 μL, 0.50%<br/> 2500 μL: 15 μL, 0.60%<br/> 1000 μL: 7 μL, 0.70%

★★★★★
Variable Volume Pipette LBN-VP108

Volume Range: 2 to 10 mL

Increment: 0.1 mL

Test Volume: 10 mL, 5 mL, 2 mL

Accuracy Error: 10 mL: 60 μL, 0.60%<br/> 5 mL: 60 μL, 1.20%<br/> 2 mL: 60 μL, 3.00%

★★★★★