Variable Volume Pipette LBN-VP104 covers a volume range of 20 to 200 μL, with increments of 1μL for precise liquid dispensing. It employs a spring-loaded design for its tip cones for enhanced reliability and performance. It withstands autoclaving at 121°C, ensuring thorough sterilization to maintain Sample integrity. Our pipette offers user-friendly operation and provides accurate results through easy calibration and maintenance.
Volume Range | 20 to 200 μL |
Increment | 1 μL |
Test Volume | 200 μL, 100 μL, 20 μL |
Accuracy Error | 200 μL: 1.2 μL, 0.60% 100 μL: 0.8 μL, 0.80% 20 μL: 0.6 μL, 3.00% |
Precision Error | 200 μL: 0.3 μL, 0.15% 100 μL: 0.3 μL, 0.30% 20 μL: 0.2 μL, 1.00% |
Includes a low-force tip ejector
Chemical-resistant tip cones ensure secure sealing
Meets ISO 8655 standards
Rotating dispensing head for easy pipetting
Incorporates a digital display
Finger support for user comfort
Variable Volume Pipette is employed for precise measurement and transfer of liquid volumes. It is used in various scientific fields such as biology, chemistry, biochemistry, and molecular biology.
Download Catalog for Variable Volume Pipette LBN-VP104
DownloadVolume Range : 10 to 100 μL
Increment : 1 μL
Test Volume : 100 μL, 50 μL, 10 μL
Accuracy Error : 100 μL: 0.8 μL, 0.80%
50 μL: 0.5 μL, 1.00%
10 μL: 0.3 μL, 3.00%
Volume Range : 0.5 to 10 μL
Increment : 0.1 μL
Test Volume : 10 μL, 5 μL, 1 μL
Accuracy Error : 10 μL: 0.1 μL, 1.00%
5 μL: 0.075 μL, 1.50%
1 μL: 0.025 μL, 2.50%
Volume Range : 2 to 20 μL
Increment : 0.5 μL
Test Volume : 20 μL, 10 μL, 2 μL
Accuracy Error : 20 μL: 0.18 μL, 0.90%
10 μL: 0.12 μL, 1.20%
2 μL: 0.06 μL, 3.00%
Volume Range : 5 to 50 μL
Increment : 0.5 μL
Test Volume : 50 μL, 25 μL, 5 μL
Accuracy Error : 50 μL: 0.3 μL, 0.60%
25 μL: 0.225 μL, 0.90%
5 μL: 0.1 μL, 2.00%
Volume Range : 50 to 200 μL
Increment : 1 μL
Test Volume : 200 μL, 100 μL, 50 μL
Accuracy Error : 200 μL: 1.2 μL, 0.60%
100 μL: 0.8 μL, 0.80%
50 μL: 0.5 μL, 1.00%
Volume Range : 200 to 1000 μL
Increment : 5 μL
Test Volume : 1000 μL, 500 μL, 200 μL
Accuracy Error : 1000 μL: 6 μL, 0.60%
500 μL: 3.5 μL, 0.70%
200 μL: 1.8 μL, 0.90%
Volume Range : 1000 to 5000 μL
Increment : 50 μL
Test Volume : 5000 μL, 2500 μL, 1000 μL
Accuracy Error : 5000 μL: 25 μL, 0.50%
2500 μL: 15 μL, 0.60%
1000 μL: 7 μL, 0.70%
Volume Range : 2 to 10 mL
Increment : 0.1 mL
Test Volume : 10 mL, 5 mL, 2 mL
Accuracy Error : 10 mL: 60 μL, 0.60%
5 mL: 60 μL, 1.20%
2 mL: 60 μL, 3.00%
Pipette Tip Volume : 1000 µL
Pack Size : 100 holes
Pieces : 100pcs
Color : Blue