Cryostat Microtome LBN-CR121 is a semi-automatic cryostat model with automatic and manual defrosting function. The unit has a light and smooth hand wheel with locking device on it. The microtome has a one time injected model cover, anti-fog heating glass design and a chromatic liquid crystal touch screen.
Slide Thickness Range | 0 to 100 µm |
Section Thickness Setting | 0 to 10 µm, in 1 µm increment 10 to 20 µm, in 2 µm increment 20 to 50 µm, in 5 µm increment 50 to 100 µm, in 10 µm increment |
Horizontal Specimen Stroke | 25 mm |
Vertical Specimen Stroke | 60 mm |
Specimen Clamp Max. Adjustable Angle | 12 ° |
Specimen Fast Moving Speed | 0.7 mm/s |
Max Slice Section | 55 × 55 mm |
Voltage | AC 220 V, 50 Hz |
Input Power | 650 VA |
Refrigerating Capacity | 690 W |
Dimensions (L × D × H) | 780 × 700 × 1152 mm |
Weight | 180 Kg |
Each defrost time is 15 minutes by default
Hibernation automatic or manual
UV sterilization
Semi-conductor refrigerant
Slice number and thickness calculation
Two movement speeds of specimen clamp
Specimen clamp enables to adjust triaxially with a block in the centre to go back
High precision guide rails make transmission smooth, durable and able to cut hard samples
Extra large chamber with freezing shelf holds 20 specimen discs
Equipped with a waste tray, instrument rack and blade holder
Anti-fatigue cam lock ensures blades are clamped tight
Blade clamp can be moved horizontally on the guide rail for safety and making full use of a blade
Glass anti rolling plate to adjust angle and gap with pressure plate
A pushing rod to pop the blades out
Name | Quantity |
---|---|
Specimen Disc | 10 pcs |
Fuse (2A) | 2 pcs |
Fuse (15A) | 2 pcs |
Appliance Stand | 1 pc |
Power line | 1 line |
Hexagonal Wrench | 1 set |
Brush | 1 pc |
Handle | 1 pc |
Cryostat Microtome is widely used in hospitals, medical schools, forensics, and animal and plant research units for pathological diagnosis, analysis, and research for rapid pathological section analysis.
Download Catalog for Cryostat Microtome LBN-CR121
DownloadSlice Thickness Range : 0 to 60 µm
Section Thickness Setting : 0.2 µm in 0.5 µm increment 2 to 10 µm in 1 µm increment 10 to 20 µm in 2 µm increments 20 to 60 µm in 5 µm increments
Horizontal Specimen Stroke : 20 mm
Vertical Specimen Stroke : 50 mm
Speed of Specimen Sectioning : 0 to 1.3 mm/s
Vibrating Range : 0 to 1 mm
Lifting Range of the Specimen Platform : 20 mm
Section Thickness Setting Range : 10 to 300 µm
Section Thickness Range : 0.5 to 100 µm (3 to 5 µm is the best slicing effect)
Section Thickness Setting : 0.5 to 5 µm, in 0.5 µm increment 5 to 20 µm, in 1 µm increment 20 to 60 µm, in 5 µm increment 60 to 100 µm, in 10 µm increment
Trimming Thickness : 1 to 600 µm
Trimming Thickness Settings : 1 to 10 µm, in 1 µm increment 10 to 20 µm, in 2 µm increment 20 to 50 µm, in 5 µm increment 50 to 100 µm, in 10 µm increment 100 to 600 µm in 50 µm increment
Slide Thickness Range : 0.5 to 100 µm (3 to 5 µm is the best slicing effect)
Section Thickness Setting : 0.5 to 5 µm, in 0.5 µm increment 5 to 20 µm, in 1 µm increment 20 to 60 µm, in 5 µm increment 60 to 100 µm, in 10 µm increment
Trimming Section Range : 1 to 600 µm
Trimming Thickness Settings : 1 to 10 µm, in 1 µm increment 10 to 20 µm, in 2 µm increment 20 to 50 µm, in 5 µm increment 50 to 100 µm, in 10 µm increment 100 to 600 µm, in 50 µm increment